Electric Motorized Dampers & Valves
Showing all 3 resultsSorted by latest
-
Electric Motorized Dampers & Valves
Solenoid Valve | PP PVC Fast-Acting Electric On-Off Air Control Valve
$20.00 Add to cart -
Electric Motorized Dampers & Valves
Electric Actuator Valve | PP PVC Motorized Flow Control with Position Feedback
$25.00 Add to cart -
Electric Motorized Dampers & Valves
Electric Motorized Damper | PP PVC Automated Air Volume Control Valve
$19.00 Add to cart
Electric Motorized Air Dampers & Valves for Automated Ventilation Control
PP and PVC electric actuated dampers (butterfly valves) provide automated airflow control in corrosive exhaust and ventilation systems. On/off and modulating actuator options integrate with building management systems (BMS), PLC controllers, and standalone thermostat/transmitter loops. Motorized dampers enable zone-based ventilation — closing dampers in unused zones to concentrate exhaust capacity where needed, reducing total fan energy consumption by 20-40%.
| Specification | Options |
|---|---|
| Diameter | DN50-DN2000 |
| Material | PP body + PP disc, PVC body + PVC disc |
| Actuator Type | On/off (230VAC/24VDC), modulating (0-10V / 4-20mA) |
| Torque | 10 Nm to 200+ Nm depending on diameter and pressure |
| Seal | EPDM (standard), FKM/Viton (solvent-resistant) |
| Control | Manual override, position feedback, fail-safe (spring return) |
On/off vs modulating dampers — when to use each
On/off actuators fully open or fully close — suitable for zone isolation, equipment bypass, and simple two-position applications. Modulating actuators accept 0-10V or 4-20mA control signals for proportional positioning — required for VAV (variable air volume) systems where duct pressure or flow must be continuously adjusted. Modulating dampers cost 30-50% more upfront but enable significant energy savings in multi-zone systems.
Frequently Asked Questions
Can PP dampers handle negative pressure?
Yes. PP dampers up to DN600 handle -1,500 Pa standard. Larger diameters or higher pressures use reinforced disc and shaft. Specify operating pressure range when ordering.
What control signal protocols are supported?
Standard: 0-10V DC, 4-20mA. Optional: Modbus RTU, BACnet MS/TP (requires communication-capable actuator). For BMS integration, specify the required protocol.
Are fail-safe (spring return) actuators available?
Yes. On power loss, spring-return actuators drive the damper to a preset safe position (fully open, fully closed, or 50%). Essential for safety-critical applications like emergency ventilation.